product, with strict quality control Digital I O Module factories, producing high quality Digital I O Module products." />
Send Message
Home ProductsDigital I O Module

1756-ENBT ControlLogix EtherNet/IP Bridge Module 128 LOGIX CONNECTIONS

1756-ENBT ControlLogix EtherNet/IP Bridge Module 128 LOGIX CONNECTIONS

  • 1756-ENBT ControlLogix EtherNet/IP Bridge Module 128 LOGIX CONNECTIONS
  • 1756-ENBT ControlLogix EtherNet/IP Bridge Module 128 LOGIX CONNECTIONS
1756-ENBT ControlLogix EtherNet/IP Bridge Module 128 LOGIX CONNECTIONS
Product Details:
Place of Origin: USA
Brand Name: GE
Model Number: 1756-ENBT
Payment & Shipping Terms:
Minimum Order Quantity: 1
Price: negitiation
Packaging Details: in box
Delivery Time: 3-5days
Payment Terms: T/T, Western Union
Supply Ability: 100
Contact Now
Detailed Product Description
Product Name: PLC Programmable Logic Controller 1756-ENBT Product: PLC Programmable Logic Controller
Model: 1756-ENBT Brand: AB
Voldtage: 24 VDC MA: 3 MA
LOGIX CONNECTIONS: 128 Country Of Origin: USA

1756-ENBT ControlLogix EtherNet/IP Bridge Module 128 LOGIX CONNECTIONS

 


Specifications for ControlLogix EtherNet/IP Bridge 1756-ENBT
ETHERNET/IP COMMUNICATION BRIDGE MODULE
CONTROLLOGIX
10/100 MBPS
24 VDC
3 MA
128 LOGIX CONNECTIONS
REPLACED BY 1756-EN2T

 

 

OTHER SUPERIOR PRODUCTS

Yasakawa Motor, Driver SG- Mitsubishi Motor HC-,HA-
Westinghouse Modules 1C-,5X- Emerson VE-,KJ-
Honeywell TC-,TK- GE Modules IC -
ABB Module AB Module 1756-,1759- Tourch Screen 2711-
Mitsubishi Drive MR- , Motor HA -,HC Emerson MoudlesVE- ,KJ -
Fanuc motor A0-, Drive Yokogawa transmitter EJA-
Rosemount Transmitter 3051- Schneider Module 140-
Panasonic Motor , Drive MH- Siemens Module 6ES-, Touch Screen 6AV-

 

 

EtherNet/IP Network Configuration
EtherNet/IP Communication Modules
1756-ENBT, 1756-EN2F, 1756-EN2T, 1756-EN2TP, 1756-EN2TPK, 1756-EN2TPXT, 1756-EN2TR, 1756-EN2TRXT,
1756-EN2TSC, 1756-EN2TXT, 1756-EN3TR, 1756-EWEB, 1768-ENBT
CompactLogix 5370 Controllers
EtherNet/IP Adapters
1734-AENT, 1734-AENTR, 1769-AENTR, 1794-AENT, 20-COMM-E, 22-COMM-E, 20-750-ENETR
Embedded Switches
1783-ETAP, 1783-ETAP1F, 1783-ETAP2

 

A backplane communication error may occur and trigger a complex sequence of events which can result in a 1756-L6X or 1756-L55 controller experiencing a major nonrecoverable fault, or cause other communications modules to assert. This anomaly can be triggered by using a 1756-ENBT module with unconnected message traffic in a system that does not include one or more of the following modules in the same chassis with the 1756-ENBT module: • 1756-EN2F • 1756-EN2T • 1756-EN2TR • 1756-EN3TR • 1756- EN2TXT • 1756-CN2/B • 1756-CN2R/B • 1756-CN2RXT • 1756-DNB/C • 1756-DNB/D • 1756-L7X • 1756-RM

 

 

As new firmware revisions of the 1756-ENBT module are released, previous versions of RSLogix 5000 software may not have those
newer 1756-ENBT module firmware revisions available in the Logix 5000 device selection list. To use a newer firmware revision of the
1756-ENBT module with an older version of the RSLogix 5000 software, add an older 1756-ENBT firmware revision to the project
and select compatible keying as the keying option. For example, if using version 16.00.00 of RSLogix 5000 software, selecting a 4.005
firmware revision with compatible keying will allow a revision 6.006 1756-ENBT module to function.

 

 

For I/O control, use RSLogix 5000 software version 8.02.00 or later. However, the 1756-ENBT module works with the 1756-ENET/B
selection in version 7.00.00 if the Compatible keying option is used.
– For Gateway applications, there are no software compatibility issues
with RSLogix 5000 software.
• RSLinxClassic software, version 2.30.01 or later

 

1756-ENBT ControlLogix EtherNet/IP Bridge Module 128 LOGIX CONNECTIONS 0

 

 

 

 

 
 

Contact Details
Wisdomlong Technology CO.,LTD

Contact Person: Harper

Tel: 86-13170829968

Fax: 86--25020661

Send your inquiry directly to us (0 / 3000)

Best Products
Other Products