Product Details:
Place of Origin: Germany
Brand Name: Siemens
Certification: CE
Model Number: 6ES7510-1DJ01-0AB0
Payment & Shipping Terms:
Minimum Order Quantity: 1
Price: Negotiable
Packaging Details: New in original box
Delivery Time: 3-5 days
Payment Terms: T/T
Supply Ability: 50
Contact Now
Detailed Product Description
Part No.: 6ES7510-1DJ01-0AB0 HS Code: 85371091
LKZ_FDB/ CatalogID: ST76 Product Type Designation: CPU 1510SP-1 PN
Country Of Origin: Germany Brand: Siemens

Siemens 6ES7510-1DJ01-0AB0 Redundant Power Supply Module ST76 for Industrial Automation

Product Description:

General Information

The CPU 1510SP-1 PN is a product type designation that comes with an HW functional status of FS05. Its firmware version is V2.9.

Product Function

The CPU 1510SP-1 PN comes with certain product functions. It has the ability to store and transmit I&M data, specifically, I&M0 to I&M3. This product also allows for module swapping during operation (also known as hot swapping) and supports isochronous mode, which is only available on PROFINET and with a minimum OB 6x cycle of 625 µs.

Engineering

The CPU 1510SP-1 PN can be configured or integrated using STEP 7 TIA Portal from version V17 (FW V2.9) or V13 SP1 Update 4 (FW V1.8) and above.

Configuration Control

Configuration can be controlled via dataset.

Control Elements

The CPU 1510SP-1 PN has a mode selector switch 1 as its primary control element.

 

Features:

Supply Voltage Information

The rated value for the supply voltage of this equipment is 24 V DC. There is a permissible range for the supply voltage with a lower limit of 19.2 V DC and an upper limit of 28.8 V DC.

Additionally, reverse polarity protection is included to prevent damage due to incorrect installation.

Mains Buffering

For mains/voltage failure, there is a stored energy time of 5 ms to provide temporary power.

Input Current

The current consumption at the rated value is 0.6 A. The maximum current consumption is 0.9 A. The inrush current has a maximum value of 4.7 A with a rated value for I²t of 0.14 A²·s.

Power Information

The infeed power to the backplane bus is 8.75 W. The typical power loss is 5.6 W.

 

Technical Parameters:

Memory Specs for SIMATIC card

There is one slot available for SIMATIC memory card in this device. A SIMATIC memory card is necessary to use with this device.

Work Memory Specifications
  • Integrated (for program): 100 kbyte
  • Integrated (for data): 750 kbyte
Load Memory

This device supports plug-in SIMATIC memory cards with a maximum capacity of 32 Gbyte.

Backup

The backup feature on this device is maintenance-free.

Device Model

The model number is 6ES75101DJ010AB0. This device has 8 pages, and the information presented is valid until May 15th, 2024. Please note that changes may occur without prior notice as this content is copyrighted by Siemens.

CPU Processing Times
  • For bit operations: 72 ns (typical)
  • For word operations: 86 ns (typical)
  • For fixed point arithmetic: 115 ns (typical)
  • For floating point arithmetic: 461 ns (typical)
 

Applications:

When it comes to counting and timing, there are a few different options available in the world of automation technology. For example, there are S7 counters and IEC counters to choose from. The S7 counter has a maximum number of 2,048, while the IEC counter can handle any number within the limits of the main memory. Both of these options have adjustable retentivity, meaning that they can hold onto their data for a specified amount of time.

In addition to counters, there are also timing functions available - both S7 and IEC offer timers that can handle up to 2,048 units. And like the counters, these timers also have adjustable retentivity.

When it comes to storing data, there are different options depending on what you need to save. For retentive data (which includes timers, counters, and flags), you have a maximum of 128 kbyte to work with. There is also available retentive memory for other types of data, such as bit memories, timers, counters, DBs, and technology data (axes). In general, 88 KB is the max for this type of memory.

If you need to work with flags specifically, they can have a maximum size of 16 kbyte. They are split up into 8 clock memories, each of which has a group of 8 clock memory bits. Data blocks are another storage option that allow for adjustable retentivity, but do not have a preset option. Finally, local data can be stored at a maximum of 64 kbyte per priority class or 16 KB per block.

 

Our advantage Products:

 

【Honeywell】Module DCS / PLC

 

【Emerson / Delta V】Module


【ABB】Input Output Module

 

【AB】Module / Touch Screen

 

【Rosemount】Pressure and Temperature Transmitter

 

【Yokogawa】Pressure Transmitter

 

【Yaskawa】Servo Drive / Servo Motor


【GE/Fanuc】IC69 Series PLC

 

【Mitsubishi】Servo Drive / Servo Motor


(Modicon,SMC,SICK,NORGREN,Siemens etc.)

 

 

 

Company Introduction
Siemens 6ES7510-1DJ01-0AB0 Redundant Power Supply Module ST76 for Industrial Automation 0

 

Contact Details
Wisdomlong Technology CO.,LTD

Contact Person: Becky

Tel: +86 189 3209 3361

Fax: Zhang hefei

Send your inquiry directly to us (0 / 3000)

Best Products
Other Products